Kernel driver: x86_pkg_temp_thermalÂķ
Supported chips:
x86: with package level thermal management
(Verify using: CPUID.06H:EAX[bit 6] =1)
Authors: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
ReferenceÂķ
IntelÂŪ 64 and IA-32 Architectures Software Developerâs Manual (Jan, 2013): Chapter 14.6: PACKAGE LEVEL THERMAL MANAGEMENT
DescriptionÂķ
This driver register CPU digital temperature package level sensor as a thermal zone with maximum two user mode configurable trip points. Number of trip points depends on the capability of the package. Once the trip point is violated, user mode can receive notification via thermal notification mechanism and can take any action to control temperature.
Threshold managementÂķ
Each package will register as a thermal zone under /sys/class/thermal.
Example:
/sys/class/thermal/thermal_zone1
This contains two trip points:
trip_point_0_temp
trip_point_1_temp
User can set any temperature between 0 to TJ-Max temperature. Temperature units are in milli-degree Celsius. Refer to âGeneric Thermal Sysfs driver How Toâ for thermal sys-fs details.
Any value other than 0 in these trip points, can trigger thermal notifications. Setting 0, stops sending thermal notifications.
Thermal notifications: To get kobject-uevent notifications, set the thermal zone policy to âuser_spaceâ.
For example:
echo -n "user_space" > policy