在Innovus中place_opt_design和optDesign阶段,我们经常会看到如下所示的log提示信息,核心关键词是“ Reasons for remaining drv violations”。而且告诉我们总共有819条net存在drv violation,且无法被工具优化掉。
=======================================================================
Reasons for remaining drv violations
*info: Total 819 net(s) have violations which can’t be fixed by DRV optimization.
MultiBuffering failure reasons
*info: 233 net(s): Could not be fixed because the solution degraded timing.
*info: 5 net(s): Could not be fixed because the location check has rejected the overall buffering solution.
*info: 477 net(s): Could not be fixed because term is inside don’t touch hierarchy.
*info: 3 net(s): Could not be fixed because of hinst,location,fence/region mismatch.
*info: 100 net(s): Could not be fixed because of exceeding max local density.
DRV主要就是指max transi
304




被折叠的 条评论
为什么被折叠?